The gas chromatograph has a pneumatic system that allows the carrier gas to run continuously and the tubing to be closed. Its injection system consists of a gasification chamber and a sample introduction device that vaporizes a liquid or solid sample immediately before entering the column and then quickly and quantitatively transfers it to the column. Temperature control is an important indicator of gas chromatograph equipment when it is analyzed. It directly affects the separation efficiency of the column and the sensitivity and stability of the detector. Shandong Tengzhou Luchuang Analytical Instrument Co., Ltd. believes that temperature control mainly refers to the temperature control of the vaporization chamber, detector, column box, etc., especially its high temperature control requirements. Mogroside is a sweet component of Siraitia grosvenorii.
Mogroside, also known as Mogroside (or Mogroside), has high plant content and good water solubility. At present, the product with purity of more than 98% has been used as food additive. [1] it is extracted from Mogroside, a special economic plant in Guangxi. Its sweetness is 300 times of sucrose, and its heat is zero. It has the effects of clearing heat, moistening lung, relieving cough, moistening intestines and defecating Diabetes and other diseases have preventive and therapeutic effects. Siraitia grosvenorii sweet can be used in all kinds of food. The content and sweetness of Mogroside V are both higher in Siraitia grosvenorii fruit, and its sweetness is about 300 times that of sucrose. It is a low calorie, non nutritive, non fermentative Sweetener and the main sweet ingredient.
Product Name:Organic Monk Fruit Extract
Active Ingredient:MogrosideV 25% 40% 50%
Latin Name: Siraitia grosvenorii
Mesh size: 80 Mesh
Used Part: Fruit
Grade: Healthcare products
The Specification Of Luo Han Guo Extract:
1. Luo Han Guo Extract 98% Mogroside V
2. Luo Han Guo Extract 80% Mogrosides / 25% Mogroside V
3. Luo Han Guo Extract 85% Mogrosides
4. Luo Han Guo Extract 90% Mogrosides /30% Mogroside V
5. Luo Han Guo Extract 95% Mogrosides
6. Luo Han Guo Extract 25%,30%,40%,50% Mogroside V
7. Luo Han Guo Extract Concentrated juice 60~65 Brix, 1% ~2% Mogroside V
1. Antioxdant
6. Protect liver
1. Contains zero Calories per serving!
3. Cool the lung
4. Treatment of Cough
Product Recommended
Coenzyme Q10,Coenzyme Q10 Powder,Mogroside 40%,Sucralose Powder Xi'an Tian Guangyuan Biotech Co., Ltd. , https://www.tgybiotech.com
(1) Gas chromatograph detector temperature control:
Temperature control of the thermal conductivity detector: room temperature should be added to 20 ° C to 399 ° C. The accuracy of temperature control is not more than ±0.1 °C. Temperature control of other heating units of the gas chromatograph: The room temperature index is added to the range of 20 ° C to 399 ° C. The accuracy of temperature control is not more than ±0.2 °C.
The detection limit of the hydrogen flame ionization detector is not more than 2×10-11 g/s; the noise value is not more than 0.015 mv; the drift value is not more than 0.1 mv/h; and the startup time is not more than one and a half hours. The sensitivity of the thermal conductivity detector is S≥3000mv.ml/mg, the noise value is not more than 0.035mv; the drift value is not more than 0.15mv/h; the startup time is not more than two and a half hours.
(2) Gas chromatograph column temperature control:
Range of temperature control: The room temperature index parameter is generally added to 8 ° C to 350 ° C (in 1 ° C increments), the upper limit parameter of the index parameter can be effective up to 399 ° C, although it can be used but can not guarantee the index.
Temperature control accuracy: no more than ± 0.1 ° C.
Temperature gradient: The percentage that is not greater than ±1% in the effective area of ​​the column.
The temperature rise of the program: generally fifth order.
Rate of temperature increase: generally 0.1 to 42 ° C / min (in 0.1 ° C increments).
Rate of cooling: The chamber temperature is reduced from 300 ° C to 50 ° C for no more than 4 minutes. It can automatically open the door to cool down.
Time setting: generally 9999.9 minutes.
(3) Lu Chuang professional gas chromatograph other heating unit temperature control: room temperature is generally also added to the index parameter of 20 ° C - 399 ° C. The temperature control accuracy should not exceed ±0.2 °C.
2. Decrease blood sugar
3. Anti-cancer
4. To relieve cough and expectorant
5. Improve immunity
2. Safe Even For Diabetics and Hypoglycemics!
The principle of setting three temperature control systems for gas chromatography
Why Choose us?
D-Tagatose Powder is one of the sweeteners. We have other sweeteners. The effective component of Monk Fruit Extract is Mogroside. Mogroside is 300 times sweeter than sucrose and does not produce heat. It is a valuable raw material in beverage and candy industry and the best substitute for sucrose. Aspartame powder, in food and soft drinks, usually aspartame is 180 ~ 220 times sweeter than sucrose. Erythritol Powder, In general, the relative sweetness of aspartame was negatively correlated with the concentration of control sucrose, and varied with different flavor systems, pH, tasting temperature and the concentration of sucrose or other sugars. Erythritol is a kind of filling sweetener, which is a four carbon sugar alcohol. The sweetness of erythritol is only 60% - 70% of sucrose. It has a cool taste, pure taste and no aftertaste. It can be combined with high times sweetener to inhibit the bad flavor of high times sweetener. We strongly recommend pregabalin Powder. It's the best product we sell.