The following is a brief introduction of the safety knowledge of the spray pasteurization machine by the Xiaobian of Zhucheng Lite Machinery Co., Ltd .: 1. Before the start of the white shift, complete the refueling according to the regulations, and check the sterilizer and the chain for foreign objects; 2. Check whether the water level of each tank in the sterilization and warming machine meets the requirements. The water level is low and the maintenance worker is inspected and repaired, and the water is added in time to check whether the steam pressure is normal; rinse the scorpion in the water tank; 3. Start the production process and check whether the working condition of the pump is normal; check whether the sprinkler pipe and the sprinkler are unblocked; 4. Open the steam door and start heating up. When the temperature of each tank reaches the requirement, the bottle can be bottled; 5. Ensure the temperature of each tank to ensure the quality; 6. Ensure that the steam pressure is ≥0.5MPa and the water pressure is 0.04-0.2MPa. It is strictly prohibited to drive below the process requirements; 7. Check the net and tweezers every two hours and rinse them in time; 8. After the night shift is completed, close the steam gate and then turn off the pump. Finally, turn off the sterilizer and refuel the equipment. 9. Unblock the sprinkler pipe and nozzle in time after completion of the work; 10. Regularly release water. When draining water, you must use a sewage pipe to regularly burn and descale the system. In each temperature zone of the pasteurization and spray cooler, the vessel is sprayed with water of different temperatures, namely the sterilization phase and the cooling phase. The water that is sprayed onto the cooler container will become hot. This part of the hot water is used to cool the hotter container that has been sterilized, so that the container can be gradually cooled. The loss of taste caused by overheating can prevent the sudden change of the thermal stress of the container and cause the broken bottle or bottle to be deformed. And after the heating zone and the cooling zone are connected to each other, the energy is well reclaimed - this is called the principle of energy regeneration. The spray pasteurizer takes full advantage of this heat balance principle, which consumes very little energy and uses only a limited amount of energy in the sterilization area. The above is all the inner cylinders of the safety knowledge of the Leite mechanical spray pasteurization machine in Zhucheng City . Please treat the new and old customers seriously. 3mm Pediatric Laparoscopic Forceps 3mm Pediatric Laparoscopic Forceps,Pediatric Laparoscopic Forceps,Pediatrics Curved Scissors,Laparoscopic Straight Scissors Tonglu WANHE Medical Instrument Co., Ltd , https://www.tlvanhurhealth.com Instructions for the use of spray pasteurization machines