Solar pest insect reporting lamp installation method

<

1. Installation: build a cement pedestal at the installation site. Install the mounting bolts on the pedestal according to the installation hole on the bottom of the automatic insect detection lamp (or reserve the anchor bolt holes. Insert the bolts during installation) After the hole is installed, the test lamp is installed and then filled with cement slurry into the bolt hole). After the base cement is solidified, the test light is fastened to the base.

2. If you want to fix the lamp body to the work site for a long time, keep the locking device when designing the base.

3. Turn on the power, the power indicator light is on, push up the leakage protection device, turn on the controller power switch, the switch indicator light is on; the display enters the loading state - the display starts to start. Enter the main page first to see the menu bar display: timing control, manual control, data settings, 20XX-XX-XX XX: XX (date display) button.

Select the data setting button in the menu bar to set the parameters and select the time parameters to be worked.

(1) Select the data setting button in the menu bar to set the parameters and select the time parameters to be operated.

a. Time period setting: set the working time period.

b. Interval time: set the time when the two movable doors of the processing bin are alternately opened.

c. System time: adjust the time and date of the system.

(2) After setting the data, select the timing control button in the menu bar. After entering, click the timer to start, and the system can run according to the preset parameters.

(3) Click the timer to stop, the system exits the timing working mode and enters the light control mode.

(4) first turn off the timing control, then click the manual control menu button, the system enters the manual control mode, you can see the submenu buttons, respectively, the rollover, insect killing lamp, heating tube, emptying the insecticidal bin, emptying the drying bin, Point-to-point control can be achieved by changing positions.

(5) There is a current status column in the menu bar to view the status of the machine in real time.

4. Check before use (daytime): Open the door of the test light, and check the operation of the test light by the following steps through the display panel inside the cabinet.

(1) Cover the light sensor, the light trap light is on - it is working at night.

(2) Using the clear water droplets into the rain sensor, the trap light tube is immediately extinguished, and the whole lamp enters a rainproof state. After the rain stopped, the rainwater in the rain sensor was about 1 minute later, and the trap light source was turned back on.

(3) After a few minutes (time adjustable), there is a sound of insecticidal worm disk rotation in the cabinet; then the same time is spent, drying the worm disk rotation - the far infrared processing chamber completes the worm.

(4) Remove the obstruction on the light sensor, and the light source of the trap light is still working. After about 1 minute, the trap light is extinguished, and the dumping position is turned to the rainy state, the insecticidal warehouse rotates, the drying chamber rotates, and the warehouse is changed. Rotate one grid to complete the conversion of the insect box. At this time, the test light completes a day and night simulation cycle and returns to the standby state.

5, enter the manual control menu, press the warehouse once, turn the warehouse disk to rotate a grid position. The turntable is rotated clockwise, and the insect box at the insect bed is rotated six times to reach the door of the cabinet for easy insect picking.

Disposable Silicone Laryngeal Mask Airway

The Laryngeal Mask Airway is the non-surgical and invasive device used for human body cavity in the short time, which is not in association with active medical devices. It can establish an artificial airway when the cuff of laryngeal mask tight covers the throat during the anesthesia and emergency treatment. It is also useful in situations where manipulation of the head or neck to facilitate endotracheal intubation is difficult or unsuccessful.

The Silicone Laryngeal Mask is with perture bar or without aperture bar avaliable. The purpose of aperture bar is in order to prevent a large epiglottis from falling into the aperture, blocking and occluding the airway.

Features:

1. Latex free, single use, EO sterilization, CE mark;
2. Individual paper-poly pouch or blister is optional;
3. Made of medical-grade silicone;
4. The color of the cuff can be customized: blue, yellow, clear;
5. Both with and without aperture bar is available;
6. Smooth connecting, very high quality.


Standard disposable silicone laryngeal mask airway and reinforced laryngeal mask airway can be selected



Surgical Laryngeal Mask Airway,Lma Laryngeal Mask Airway,Medical Disposable laryngeal mask airway

Hangzhou Trifanz Medical Device Co., Ltd , https://www.cfzmed.com