Drainage Tube,Surgical Supply,Disposable Medical Henso Medical Co., Ltd. , http://www.hzurology.com
Brief Introduction:
Three control modes: Pre-warm mode, manual mode and baby mode controlled by micro-computer;
Set temperature and baby temperature can be displayed separately;
Horizon angle of warmer module and inclination of the bassinet can be adjusted;
The panels around bassinet can be disassembled;
APGAR timer;
Failure alarm indication;
RS232 connector;
Disposable skin temperature sensor is optional.
Standard Configuration:
Main body (including the warmer module, temperature controller, bassinet, stand), I.V. Pole, tray.
Specification:Â
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 600VA
Mode of control: Pre-warm mode control, manual mode control and baby mode control by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Skin temperature display range: 5ºC-65ºC
Accuracy of skin temperature sensor: ±0.2ºC
Temperature uniformity of mattress: ≤2ºC
Angle of heater head: 0°, 30°, 45°for two ways;
Inclination of the bassinet: five tilt position;
APGAR timer: audible and visible alarm when the device runs to 50″~1′,4′50″~5′,9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking  alarm  and  so on.
Â
Incubadora Radiante Cuna Termica Neonatal Infant Radiant Warmer
Brief Introduction:
Three control modes: Pre-warm mode, manual mode and baby mode controlled by micro-computer;
Set temperature and baby temperature can be displayed separately;
Horizon angle of warmer module and inclination of the bassinet can be adjusted;
The panels around bassinet can be disassembled;
APGAR timer;
Failure alarm indication;
RS232 connector;
Disposable skin temperature sensor is optional.
Standard Configuration:
Main body (including the warmer module, temperature controller, bassinet, stand), I.V. Pole, tray.
Specification:Â
Power requirement: AC220V-230V/50Hz or AC110-120V/50-60Hz, 600VA
Mode of control: Pre-warm mode control, manual mode control and baby mode control by micro-computer
Baby mode temperature control range: 34.5-37.5ºC
Skin temperature display range: 5ºC-65ºC
Accuracy of skin temperature sensor: ±0.2ºC
Temperature uniformity of mattress: ≤2ºC
Angle of heater head: 0°, 30°, 45°for two ways;
Inclination of the bassinet: five tilt position;
APGAR timer: audible and visible alarm when the device runs to 50″~1′,4′50″~5′,9′50″~10′;
Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking  alarm  and  so on.
Â
Incubadora Radiante Cuna Termica Neonatal Infant Radiant Warmer
Model NO.: IRW-9000
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: Double Sides Phototherapy Radiant Box
Modes: Pre-Warm ,Manual or Automatic
Oxygen Cylinder: No
X-ray Cassette: No
Tilt Angle of Bed: No
Heater Head: Adjusted
LED Observation Light: No
Low Pressure Aspirator: No
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
Model NO.: IRW-9000
Classification: Infant Radiant Warmer
Applications: Nicu,Operating Room
Phototherapy Unit: Double Sides Phototherapy Radiant Box
Modes: Pre-Warm ,Manual or Automatic
Oxygen Cylinder: No
X-ray Cassette: No
Tilt Angle of Bed: No
Heater Head: Adjusted
LED Observation Light: No
Low Pressure Aspirator: No
Trademark: Perlong
Transport Package: Carton
Specification: with trolley
Origin: China
HS Code: 90189090
Incubadora Radiante Cuna Termica Neonatal Infant Radiant Warmer